APC

APC Back-UPS 650VA (BE650G1)

The official replacement cartridge for the BE650G1 is RBC17, a 12 V, 9 Ah lead-acid cartridge. Several other compact Back-UPS models share this SKU; some nearby models are not user-replaceable at all.

Official replacement cartridge

RBC17

Official SKURBC17
Voltage12 V
Capacity9 Ah
TypeLead-acid
Cartridge quantity1
Cartridge warranty2-year repair or replace
AssemblyFully assembled and ready for use

Official RBC17 product page

UPS specifications (from the official datasheet or product page)

Family / product nameAPC Back-UPS 650VA (BE650G1)
VA rating650 VA
Watt rating390 W
TopologyStandby
WaveformStepped approximation to a sine wave
Input voltage120 V AC, 1 phase
Form factorTower
Outlets8 × NEMA 5-15R (4 battery + surge, 4 surge-only)
Transfer time8 ms typical, 12 ms maximum
Typical recharge time24 hours (typical)
Typical battery life2–5 years
UPS battery voltage12 V
UPS battery capacity9.0 Ah
Official RBC quantity1
User-replaceable batteryYes (official table and datasheet: user-replaceable / removable battery)
UPS warranty (as published)36 months (UPS), 12 months (battery supplied with the UPS)

Related models

How to replace the battery

This is a 12 V, single-cartridge Back-UPS, not a 24 V Back-UPS Pro. Typical recharge is long: the official datasheet lists 24 hours.

  1. Confirm the label says BE650G1. Do not assume every “Back-UPS 650” is user-replaceable; Schneider’s official table marks several nearby models as having no RBC available.
  2. Read the official BE650G1 user documentation and the RBC17 instruction sheet.
  3. Shut the UPS down and unplug it unless the official sheet for this model says otherwise.
  4. Install the complete RBC17 cartridge, then allow up to the official 24-hour typical recharge before judging runtime.
  5. Recycle the used cartridge.

These are orientation steps, not a substitute for the manufacturer’s instruction sheet. Lead-acid UPS batteries can present electrical and chemical hazards.

Warranty considerations

Genuine vs third-party packs. This guide lists only the official manufacturer cartridge. Third-party kits are widely sold, but this site does not verify their dimensions, runtime, or safety against the OEM specification. Schneider Electric’s FAQ on genuine APC RBCs states that a non-APC battery may result in lower runtime, damage the UPS, create hazardous conditions, or void safety certifications, and that it will void APC’s Equipment Protection Policy. If you still consider an aftermarket pack, treat voltage, capacity, and physical fit as necessary starting points — not as proof of compatibility — and expect warranty terms to change.

When to replace the whole UPS instead

Where to buy (affiliate placeholders)

These are ordinary search links, not tracked affiliate tags. When a program is joined, replace the href and keep the data-affiliate attribute.

Search Amazon for APC RBC17 Affiliate placeholderSearch eBay for APC RBC17 Affiliate placeholder

Affiliate disclosure

FAQ

What battery does a BE650G1 take?

The official BE650G1 datasheet and the USA/Canada Back-UPS table both list RBC17. The official RBC17 page describes it as a 12 V, 9 Ah lead-acid cartridge with a 2-year repair-or-replace warranty.

Can I use RBC17 in any Back-UPS?

No. Official documentation assigns RBC17 only to specific models (including BE650G1, BE850G2, BE900G3, BR700G, and BX850M). Other units use APCRBC154, APCRBC110, or have no user-replaceable battery.

Sources