APC Back-UPS 1350, Compact Tower, 1350VA, 120V, AVR, LCD (BX1350M)
The official USA/Canada replacement cartridge for the BX1350M is APCRBC123, a 24 V, 7 Ah lead-acid cartridge with a 2-year repair-or-replace warranty. It is not the same cartridge as its BX-series siblings.
Official replacement cartridge
APCRBC123
| Official SKU | APCRBC123 |
|---|---|
| Voltage | 24 V |
| Capacity | 7 Ah |
| Type | Lead-acid |
| Cartridge quantity | 1 |
| Cartridge warranty | 2-year repair or replace |
| Assembly | 7 Ah, 24 Vdc replaceable battery for APC Back-UPS and Smart-UPS line-interactive units |
Official APCRBC123 product page
UPS specifications (from the official datasheet or product page)
| Family / product name | APC Back-UPS 1350, Compact Tower, 1350VA, 120V, AVR, LCD (BX1350M) |
|---|---|
| VA rating | 1350 VA |
| Watt rating | 810 W |
| Input voltage | 120 V |
| Form factor | Compact tower |
| Outlets | 10 × NEMA outlets (5 surge-only, per the official product name) |
| Official RBC quantity | 1 |
| User-replaceable battery | Yes (official Back-UPS table: user-replaceable battery) |
Related models
- BX1500M: Same BX “M” family and the same Schneider troubleshooting FAQ, but the official cartridge is APCRBC124 (24 V, 9 Ah), not APCRBC123.
- BX1000M: Schneider’s official table and BX troubleshooting FAQ assign APCRBC158 to the BX1000M.
- BX850M: Schneider’s official table and BX troubleshooting FAQ assign RBC17 to the BX850M.
- BR1000G, BX1000G, BX1300G: Schneider’s official table and the Back-UPS XS/RS “G” install FAQ also assign APCRBC123 to these units. They are different UPS models; confirm the label on yours.
How to replace the battery
Schneider publishes an instruction sheet with the APCRBC123 cartridge and a user guide for the BX1350M (both linked from the official product pages). Follow those official documents.
- Confirm the rear or bottom label says BX1350M. Close relatives use different official SKUs: BX1500M uses APCRBC124, BX1000M uses APCRBC158, and BX850M uses RBC17.
- If backup time is short right after an outage, Schneider’s BX troubleshooting FAQ says to charge the battery cartridge for 16 hours before deciding it has reached end of life.
- Read the BX1350M user guide and the APCRBC123 instruction sheet from the official product pages before opening the battery compartment.
- Install the complete APCRBC123 cartridge as a unit. Recycle the used pack (the official cartridge page notes support for APC-authorized recycling).
- After a full charge, check that the REPLACE BATTERY indicator has cleared.
These are orientation steps, not a substitute for the manufacturer’s instruction sheet. Lead-acid UPS batteries can present electrical and chemical hazards.
Warranty considerations
- A separately purchased APCRBC123 is advertised on Schneider’s official page with a 2-year warranty (repair or replace).
- Using a non-APC battery will void APC’s Equipment Protection Policy, according to Schneider Electric FAQ FA328895.
When to replace the whole UPS instead
- If a genuine APCRBC123 is installed and fully charged and the UPS still shows errors F03–F09, Schneider’s troubleshooting FAQ says those cannot be corrected by the user; contact Schneider technical support.
- If the REPLACE BATTERY indicator stays on after a new genuine cartridge and a full charge, the UPS itself may be at fault.
Where to buy (affiliate placeholders)
These are ordinary search links, not tracked affiliate tags. When a program is joined, replace the href and keep the data-affiliate attribute.
Search Amazon for APC APCRBC123 Affiliate placeholderSearch eBay for APC APCRBC123 Affiliate placeholder
FAQ
What battery does a BX1350M take?
Schneider Electric’s official USA/Canada Back-UPS table and the BX850M/BX1000M/BX1350M/BX1500M troubleshooting FAQ both list APCRBC123. The official APCRBC123 page describes it as a 24 V, 7 Ah lead-acid cartridge with a 2-year repair-or-replace warranty.
Can I use the BX1500M battery (APCRBC124) instead?
No. Schneider assigns APCRBC124 (24 V, 9 Ah) to the BX1500M and APCRBC123 (24 V, 7 Ah) to the BX1350M. Order the SKU listed for your exact model.
Is the BX1350M battery user-replaceable?
Yes. Schneider’s official USA/Canada table marks the BX1350M as a user-replaceable battery.
Sources
- APC BX1350M official product page (1350 VA / 810 W, 120 V, compact tower, AVR, LCD, 10 NEMA outlets with 5 surge)
- Official USA/Canada Back-UPS replacement battery table (BX1350M = APCRBC123, user replaceable)
- BX850M / BX1000M / BX1350M / BX1500M troubleshooting (BX1350M = APCRBC123; 16-hour recharge)
- APCRBC123 official U.S. product page (24 V, 7 Ah, 2-year warranty)
- Why use only a genuine APC RBC